STOE STADI-MP SYSTEM
- Transmission / Debye-Scherrer, flat plate andBragg-Brentano
mode - All geometries running with pure Ka1 radiation -
High resolution yielding well-defined peak profiles -
Stress and texture diffraction using an open Eulerian
cradle - Extensive control and evaluation software
WinXPOW - Various high / and low temperature attachments
and sample changers - Scintillation counter,
linear PSD and imaging plate detector
|
|
|

|
STOE STADI-P SYSTEM
- Transmission/Debye- Scherreror Bragg-Brentano mode -
High resolution yielding well- defined peak profiles -
Extensive software package WinXPOW - Scintillation
counter, position sensitive and imaging plate
detectors - Ge(111) monochromator for Fe, Co, Cu
or Mo radiation yielding pure Ka1 radiation -
Analysis of air- and moisture-sensitive samples
as well as microsamples

|
|
|

|
STOE STADI-P COMBI SYSTEM
- 96-fold sample stage - user definable x,y grid
- pure K¥á1 radiation - transmission geometry -
linear PSD or imaging plate detector - no compromise
in resolution - fully automated evaluation software -
flexible choice of reference parameters
|
|
|

|
STOE T/T SYSTEM
- 2Theta range from -10° to 168° - Measuring
circle of 270 mm radius - Tube translation for optimal
primary beam intensity - All possible scan modes -
Adjusting kit for optimal alignment - Sample maintaines
in horizontal position - Highest reproducibility
- Precision slit system - Soller slits -
All optional devices are easily adaptable - FWHM
down to 2T=0.025°

|
|
|

|
STOE IPDS-II SYSTEM
- Active Imaging Plate diameter of 340 mm, max. 2¥è
= 77° - 2-circle goniometer, 180° range,
unlimited ¥õ range - Suitable for Cu, Mo and Ag radiation -
Solutions for grown-together crystals, twins and modulatedstructures -
Accurate detection of superstructures - Various attachments
for non-ambient methods

|
|
|

|
STOE IPDS-II 2T SYSTEM
- Active Imaging Plate diameter of 340 mm - Dynamic
range >1:105 - Two circle goniometer,from 0 -
180°, unlimited - 5 positions: 0°, 15°,
30°, 45°, 60° 2T - 2T max. = 137° -
Structure solutions for small molecules as well as for
proteines - Electron density calculations - Investigations
of powder samples - High- and low-temperature attachments

|
|
|

|
STOE HIGH-TEMPERATURE ATTACHMENTS
- Continuous sample spining leading to effective
particle randomization - Well-defined sample position
yielding meaningful lattice constants -
Fully integrated PC-based data collection and
temperature control - Quick exchange against other
sample stages and easy alignment
|
|
|

|
STOE POSITION SENSITIVE
DETECTORS

|
|
|

|
STOE SAMPLE HOLDERS

|
|
|
|
|
|
|
|
|
|